smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.16.1-arch1-1] (local build) Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Toshiba 3.5" DT01ACA... Desktop HDD Device Model: TOSHIBA DT01ACA100 Serial Number: Y6BKLE1NS LU WWN Device Id: 5 000039 febf245f8 Firmware Version: MS2OA7L0 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: In smartctl database 7.5/5706 ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Thu Aug 21 15:13:28 2025 EEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 7022) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 117) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 086 086 016 Pre-fail Always - 10223620 2 Throughput_Performance 0x0005 142 142 054 Pre-fail Offline - 69 3 Spin_Up_Time 0x0007 143 143 024 Pre-fail Always - 142 (Average 179) 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 3460 5 Reallocated_Sector_Ct 0x0033 073 073 005 Pre-fail Always - 626 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 115 115 020 Pre-fail Offline - 34 9 Power_On_Hours 0x0012 098 098 000 Old_age Always - 15573 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 2819 192 Power-Off_Retract_Count 0x0032 098 098 000 Old_age Always - 3561 193 Load_Cycle_Count 0x0012 098 098 000 Old_age Always - 3561 194 Temperature_Celsius 0x0002 171 171 000 Old_age Always - 35 (Min/Max 15/48) 196 Reallocated_Event_Count 0x0032 069 069 000 Old_age Always - 717 197 Current_Pending_Sector 0x0022 094 094 000 Old_age Always - 296 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 20 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 20 occurred at disk power-on lifetime: 15568 hours (648 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 10 d0 88 a3 01 Error: UNC at LBA = 0x01a388d0 = 27494608 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 80 d8 60 88 a3 40 08 06:48:31.509 READ FPDMA QUEUED 61 40 50 58 31 05 40 08 06:48:31.509 WRITE FPDMA QUEUED 61 18 08 d0 7b 21 40 08 06:48:27.147 WRITE FPDMA QUEUED 60 40 d0 20 88 a3 40 08 06:48:27.018 READ FPDMA QUEUED 60 20 c8 00 88 a3 40 08 06:48:27.018 READ FPDMA QUEUED Error 19 occurred at disk power-on lifetime: 15568 hours (648 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 20 e0 db 0e 0a Error: UNC at LBA = 0x0a0edbe0 = 168745952 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 20 88 e0 db 0e 40 08 06:46:16.243 READ FPDMA QUEUED 61 40 80 58 2f 05 40 08 06:46:16.243 WRITE FPDMA QUEUED ef 10 03 00 00 00 a0 08 06:46:16.243 SET FEATURES [Enable SATA feature] ef 90 03 00 00 00 a0 08 06:46:16.243 SET FEATURES [Disable SATA feature] ef 10 02 00 00 00 a0 08 06:46:16.243 SET FEATURES [Enable SATA feature] Error 18 occurred at disk power-on lifetime: 15568 hours (648 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 e0 dc 0e 0a Error: WP at LBA = 0x0a0edce0 = 168746208 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 61 40 00 58 2f 05 40 08 06:46:12.448 WRITE FPDMA QUEUED 60 20 a8 e0 db 0e 40 08 06:46:12.448 READ FPDMA QUEUED 60 00 a0 e0 dc 0e 40 08 06:46:12.448 READ FPDMA QUEUED ea 00 00 00 00 00 a0 08 06:46:12.448 FLUSH CACHE EXT ef 10 03 00 00 00 a0 08 06:46:12.447 SET FEATURES [Enable SATA feature] Error 17 occurred at disk power-on lifetime: 15568 hours (648 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 20 e0 db 0e 0a Error: WP at LBA = 0x0a0edbe0 = 168745952 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 61 18 00 50 fa 16 40 08 06:46:08.438 WRITE FPDMA QUEUED 60 20 f0 e0 db 0e 40 08 06:46:08.438 READ FPDMA QUEUED ef 10 03 00 00 00 a0 08 06:46:08.437 SET FEATURES [Enable SATA feature] ef 90 03 00 00 00 a0 08 06:46:08.437 SET FEATURES [Disable SATA feature] ef 10 02 00 00 00 a0 08 06:46:08.437 SET FEATURES [Enable SATA feature] Error 16 occurred at disk power-on lifetime: 15568 hours (648 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 c8 18 dc 0e 0a Error: UNC at LBA = 0x0a0edc18 = 168746008 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 88 e0 dc 0e 40 08 06:45:52.547 READ FPDMA QUEUED 61 08 80 50 2f 05 40 08 06:45:52.547 WRITE FPDMA QUEUED 60 00 78 e0 db 0e 40 08 06:45:52.547 READ FPDMA QUEUED ea 00 00 00 00 00 a0 08 06:45:52.518 FLUSH CACHE EXT 61 28 68 28 2f 05 40 08 06:45:48.651 WRITE FPDMA QUEUED SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. The above only provides legacy SMART information - try 'smartctl -x' for more